WPD T90, Flanged Woltman-Type Hot Water Meter, DN100 (4”), Q3 160 m³/h, L 250 mm, up to 90 °C, R100 Horizontal, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module
WPD T90, Flanged Woltman-Type Hot Water Meter, DN80 (3”), Q3 100 m³/h, L 225 mm, up to 90 °C, R100 Horizontal, 8 × M16, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module
WPD T90, Flanged Woltman-Type Hot Water Meter, DN65 (2½”), Q3 63 m³/h, L 200 mm, up to 90 °C, R100 Horizontal, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module
WPD T90, Flanged Woltman-Type Hot Water Meter, DN50 (2”), Q3 40 m³/h, L 200 mm, up to 90 °C, R100 Horizontal, 4 × M16, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module
WPD, Flanged Woltman-Type Cold Water Meter, DN100 (4”), Q3 100 / 160 m³/h, L 250 / 350 / 360 mm, up to 50 °C, R160 Horizontal / R63 Vertical, 8 × M16, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
WPD, Flanged Woltman-Type Cold Water Meter, DN80 (3”), Q3 63 / 100 m³/h, L 200 / 225 / 300 / 350 mm, up to 50 °C, R160 Horizontal / R63 Vertical, 8 × M16, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
WPD, Flanged Woltman-Type Cold Water Meter, DN65 (2½”), Q3 40 / 63 m³/h, L 200 / 300 mm, up to 50 °C, R160 Horizontal / R63 Vertical, 4 × M16, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
WPD, Flanged Woltman-Type Cold Water Meter, DN50 (2”), Q3 25 / 40 / 63 m³/h, L 200 / 270 / 300 mm, up to 50 °C, R160 Horizontal / R50–63 Vertical, 4 × M16, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
MTWD-M-CC, Multi-Jet Dry-Dial Hot Water Meter, DN40 (1½”), Q3 16 m³/h, L 300 mm, up to 90 °C, R80 Horizontal / R40 Vertical, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
MTWD-M-CC, Multi-Jet Dry-Dial Hot Water Meter, DN32 (1¼”), Q3 10 m³/h, L 260 mm, up to 90 °C, R80 Horizontal / R40 Vertical, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
MTWD-M-CC, Multi-Jet Dry-Dial Hot Water Meter, DN25 (1”), Q3 6.3 / 10 m³/h, L 260 mm, up to 90 °C, R80 Horizontal / R40 Vertical, IP68, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
MTKD-M, Multi-Jet Dry-Dial Cold Water Meter, DN40 (1½”), Q3 16 m³/h, L 300 mm, up to 50 °C, R160 Horizontal / R40 Vertical, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
MTKD-M, Multi-Jet Dry-Dial Cold Water Meter, DN32 (1¼”), Q3 6.3 / 10 m³/h, L 260 mm, up to 50 °C, R160 Horizontal / R40–50 Vertical, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
MTKD-M, Multi-Jet Dry-Dial Cold Water Meter, DN25 (1”), Q3 6.3 / 10 m³/h, L 260 mm, up to 50 °C, R160 Horizontal / R40–50 Vertical, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
ETKD, Single-Jet Dry-Dial Cold Water Meter, DN20 (¾”), Q3 2.5 / 4 m³/h, L 130 mm, up to 50 °C, R80 Horizontal / R40 Vertical, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
ETWD, Single-Jet Dry-Dial Hot Water Meter, DN20 (¾”), Q3 2.5 / 4 m³/h, L 130 mm, up to 90 °C, R80 Horizontal / R40 Vertical, Without Module or with Pulse / M-Bus / wM-Bus Module, MID
HME0344, Ultrasonic Heat Meter, M-Bus (wM-Bus optional), Installation: Return line, Application: Heating and cooling, Body: DN300 (12”), Nominal Flow Qn: 600 m³/h, Connection Size: DN300 Flange, Body Length L: 500 mm, Germany MID, Class 2
HME0054, Ultrasonic Heat Meter, M-Bus / wM-Bus + 3 Pulse, Installation: Return line, Application: Heating and cooling, Body: DN40 (1½”), Nominal Flow Qn: 10 m³/h, Connection Size: 2” Threaded, Body Length L: 300 mm, 1.5 m JUMO PT1000 Sensor, Germany MID, Class 2
HME0221, Ultrasonic Heat Meter, M-Bus / wM-Bus + 3 Pulse, Installation: Return line, Application: Heating and cooling, Body: DN32 (1¼”), Nominal Flow Qn: 6 m³/h, Connection Size: 1½” Threaded, Body Length L: 260 mm, 1.5 m JUMO PT1000 Sensor, Germany MID, Class 2
HME0053, Ultrasonic Heat Meter, M-Bus / wM-Bus + 3 Pulse, Installation: Return line, Application: Heating and cooling, Body: DN25 (1”), Nominal Flow Qn: 6 m³/h, Connection Size: 1¼” Threaded, Body Length L: 260 mm, 1.5 m JUMO PT1000 Sensor, Germany MID, Class 2
C5 IUF Ultrasonik Isı Sayacı, M-Bus ya da RF & wM-Bus, Dönüş Hattı, Isıtma/Soğutma, DN20 3/4’’ Qn: 2,5 m³/h, Dişli, L:130 mm, 1,5m JUMO Sensör, Almanya MID, Class 2
- Bu üründe Haberleşme Modülü (M-Bus & RF wM-Bus) seçimi yapmanız gerekmektedir.
HME0343, Ultrasonic Heat Meter, M-Bus (wM-Bus optional), Installation: Return line, Application: Heating and cooling, Body: DN250 (10”), Nominal Flow Qn: 400 m³/h, Connection Size: DN250 Flange, Body Length L: 600 mm, Germany MID, Class 2
HME0342, Ultrasonic Heat Meter, M-Bus (wM-Bus optional), Installation: Return line, Application: Heating and cooling, Body: DN200 (8”), Nominal Flow Qn: 250 m³/h, Connection Size: DN200 Flange, Body Length L: 500 mm, Germany MID, Class 2
HME0341, Ultrasonic Heat Meter, M-Bus (wM-Bus optional), Installation: Return line, Application: Heating and cooling, Body: DN150 (6”), Nominal Flow Qn: 150 m³/h, Connection Size: DN150 Flange, Body Length L: 500 mm, Germany MID, Class 2
HME0340, Ultrasonic Heat Meter, M-Bus (wM-Bus optional), Installation: Return line, Application: Heating and cooling, Body: DN125 (5”), Nominal Flow Qn: 100 m³/h, Connection Size: DN125 Flange, Body Length L: 350 mm, Germany MID, Class 2
HME0058, Ultrasonic Heat Meter, M-Bus (wM-Bus optional), Installation: Return line, Application: Heating and cooling, Body: DN100 (4”), Nominal Flow Qn: 60 m³/h, Connection Size: DN100 Flange, Body Length L: 360 mm, Germany MID, Class 2
HME0339, Ultrasonic Heat Meter, M-Bus (wM-Bus optional), Installation: Return line, Application: Heating and cooling, Body: DN80 (3”), Nominal Flow Qn: 40 m³/h, Connection Size: 3” Flange, Body Length L: 225 mm, JUMO PT1000 Sensor, Germany MID, Class 2
HME0338, Ultrasonic Heat Meter, M-Bus (wM-Bus optional), Installation: Return line, Application: Heating and cooling, Body: DN65 (2½”), Nominal Flow Qn: 25 m³/h, Connection Size: 2½” Flange, Body Length L: 200 mm, JUMO PT1000 Sensor, Germany MID, Class 2
HME0337, Ultrasonic Heat Meter, M-Bus (wM-Bus optional), Installation: Return line, Application: Heating and cooling, Body: DN50 (2”), Nominal Flow Qn: 15 m³/h, Connection Size: 2” Flange, Body Length L: 200 mm, JUMO PT1000 Sensor, Germany MID, Class 2
C5-ISF, Mechanical Heat Meter, M-Bus / wM-Bus + 3 Pulse, Installation: Return line, Application: Heating, Body: DN20 (¾”), Nominal Flow Qn: 2.5 m³/h, Connection Size: 1” Threaded, Body Length L: 130 mm, JUMO PT1000 Sensor, Germany MID, Class 3