Wireless (RF / wM-Bus) Heat Meters
A wireless heat meter transmits its meter reading by radio signal; there is no need to enter the apartment or run communication cables through the building to read it. This category includes heat meters offered with the wireless wM-Bus (wireless M-Bus) option: the Minol Zenner C5 IUF ultrasonic heat meter (DN20–DN40) and the Minol Zenner C5 ISF mechanical heat meter (DN20). All wired M-Bus models can be found in the heat meters category.
C5 IUF Ultrasonik Isı Sayacı, M-Bus ya da RF & wM-Bus, Dönüş Hattı, Isıtma/Soğutma, DN20 3/4’’ Qn: 2,5 m³/h, Dişli, L:130 mm, 1,5m JUMO Sensör, Almanya MID, Class 2
- Bu üründe Haberleşme Modülü (M-Bus & RF wM-Bus) seçimi yapmanız gerekmektedir.
014U0015, Ultrasonic Heat Meter, M-Bus (wired), Installation: return pipe, Application: heating, Body: DN20 (¾”), Nominal flow Qn: 2.5 m³/h, Connection size: 1” threaded, Body length L: 130 mm, 1.5 m PT1000 sensor, Denmark MID, Class 2
C5-ISF, Mechanical Heat Meter, M-Bus / wM-Bus + 3 Pulse, Installation: Return line, Application: Heating, Body: DN20 (¾”), Nominal Flow Qn: 2.5 m³/h, Connection Size: 1” Threaded, Body Length L: 130 mm, JUMO PT1000 Sensor, Germany MID, Class 3
HME0221, Ultrasonic Heat Meter, M-Bus / wM-Bus + 3 Pulse, Installation: Return line, Application: Heating and cooling, Body: DN32 (1¼”), Nominal Flow Qn: 6 m³/h, Connection Size: 1½” Threaded, Body Length L: 260 mm, 1.5 m JUMO PT1000 Sensor, Germany MID, Class 2
014U0007, SonoSafe DN15 qp 1.5 m³/h, G¾" 110 mm, suitable for return pipe, with M-Bus module, heating only, 1 free sensor, Connection types: Threaded, Kvs: 3.87 m³/h, Medium temperature: 95 °C
014U0019, SonoSafe DN25 qp 3.5 m³/h, G1" 160 mm, suitable for return pipe, with M-Bus module, heating only, 1 free sensor, Connection types: Threaded, Kvs: 9.71 m³/h, Medium temperature: 95 °C
014U1301, SonoSelect DN15 qp 1.5 m³/h, G¾" 110 mm, return-pipe mounting, with M-Bus module, for heating/cooling, 1 free sensor, Connection types: Threaded, Kvs: 3.87 m³/h, Medium temperature: 95 °C
014U1303, SonoSelect DN20 qp 2.5 m³/h, G1" 130 mm, return-pipe mounting, with M-Bus module, for heating/cooling, 1 free sensor, Connection types: Threaded, Kvs: 6.25 m³/h, Medium temperature: 95 °C
014U1304, SonoSelect DN25 qp 3.5 m³/h, G1¼" 160 mm, return-pipe mounting, with M-Bus module, for heating/cooling, 1 free sensor, Connection types: Threaded, Kvs: 9.71 m³/h, Medium temperature: 95 °C
014U1305, SonoSelect DN25 qp 6.0 m³/h, G1¼" 260 mm, return-pipe mounting, with M-Bus module, for heating/cooling, 1 free sensor, Connection types: Threaded, Kvs: 12.79 m³/h, Medium temperature: 95 °C
HME0053, Ultrasonic Heat Meter, M-Bus / wM-Bus + 3 Pulse, Installation: Return line, Application: Heating and cooling, Body: DN25 (1”), Nominal Flow Qn: 6 m³/h, Connection Size: 1¼” Threaded, Body Length L: 260 mm, 1.5 m JUMO PT1000 Sensor, Germany MID, Class 2
187F2627, SonoMeter 40 DN15 qp 1.5 m³/h, G¾" 110 mm, suitable for return pipe, for heating/cooling, with M-Bus and RF modules, 1 free sensor, Connection types: Threaded, Kvs: 3.63 m³/h, Medium temperature: 130 °C
187F2629, SonoMeter 40 DN20 qp 2.5 m³/h, G1" 130 mm, suitable for return pipe, for heating/cooling, with M-Bus and RF modules, 1 free sensor, Connection types: Threaded, Kvs: 5.62 m³/h, Medium temperature: 130 °C
187F2631, SonoMeter 40 DN25 qp 3.5 m³/h, G1¼" 260 mm, suitable for return pipe, for heating/cooling, with M-Bus and RF modules, 2 free sensors, Connection types: Threaded, Kvs: 11.67 m³/h, Medium temperature: 130 °C
187F2632, SonoMeter 40 DN25 qp 6 m³/h, G1¼" 260 mm, suitable for return pipe, for heating/cooling, with M-Bus and RF modules, 2 free sensors, Connection types: Threaded, Kvs: 18.97 m³/h, Medium temperature: 130 °C
014U1306, SonoSelect DN32 qp 6.0 m³/h, G1½" 260 mm, return-pipe mounting, with M-Bus module, for heating/cooling, 1 free sensor, Connection types: Threaded, Kvs: 12.79 m³/h, Medium temperature: 95 °C
HME0054, Ultrasonic Heat Meter, M-Bus / wM-Bus + 3 Pulse, Installation: Return line, Application: Heating and cooling, Body: DN40 (1½”), Nominal Flow Qn: 10 m³/h, Connection Size: 2” Threaded, Body Length L: 300 mm, 1.5 m JUMO PT1000 Sensor, Germany MID, Class 2
187F2633, SonoMeter 40 DN40 qp 10 m³/h, G1½" 300 mm, suitable for return pipe, for heating/cooling, with M-Bus and RF modules, 2 free sensors, Connection types: Threaded, Kvs: 23.57 m³/h, Medium temperature: 130 °C
187F2635, SonoMeter 40 DN50 qp 15 m³/h, 270 mm flanged, suitable for return pipe, for heating/cooling, with M-Bus and RF modules, 2 free sensors, Connection types: Flange, Kvs: 43.3 m³/h, Medium temperature: 130 °C
187F2636, SonoMeter 40 DN65 qp 25 m³/h, 300 mm flanged, suitable for return pipe, for heating/cooling, with M-Bus and RF modules, 2 free sensors, Connection types: Flange, Kvs: 55.9 m³/h, Medium temperature: 130 °C
187F2637, SonoMeter 40 DN80 qp 40 m³/h, 300 mm flanged, suitable for return pipe, for heating/cooling, with M-Bus and RF modules, 2 free sensors, Connection types: Flange, Kvs: 94.28 m³/h, Medium temperature: 130 °C
187F2638, SonoMeter 40 DN100 qp 60 m³/h, 360 mm flanged, suitable for return pipe, for heating/cooling, with M-Bus and RF modules, 2 free sensors, Connection types: Flange, Kvs: 141.42 m³/h, Medium temperature: 130 °C