Danfoss Valves, Actuators, Thermostats and Heat Meters
Danfoss is an engineering company founded by Mads Clausen in 1933 in Nordborg, Denmark; its Climate Solutions business develops energy-efficient heating and cooling solutions for buildings. Novus Mühendislik ve Enerji Sistemleri offers more than 300 Danfoss heating and hydronic products, all original and invoiced, with the warranty provided by the manufacturer or importer, and our technical team helps you match valve bodies, sensors and actuators. In-stock items ordered and paid by 16:00 on a business day are handed to the carrier the same day (shipping and delivery).
Featured categories: Danfoss Thermostatic Radiator Valves · Danfoss Valve Actuators · Danfoss AB-QM Pressure Independent Control Valves · Danfoss Balancing Valves · Danfoss Room Thermostats · Danfoss Heat Meters
Danfoss product families, selection guide and FAQ
| Product family | Key series / models | Typical use | Category |
|---|---|---|---|
| Valve actuators (~90) | TWA-A, TWA-K, TWA-Q, AME, AMV, NovoCon, AMZ | Zone, PICV and control valve automation | Valve actuators |
| Balancing valves (~55) | AB-QM, AB-PM, ASV-PV, FAN-Q, LENO MSV-BD, USV-I | Risers, apartment inlets, fan coils | Balancing valves |
| Heat meters (~50) | SonoSafe 10, SonoSelect, SonoMeter 40, Supercal 5 | Apartment and building energy metering | Heat meters |
| Underfloor heating and room control (~45) | Icon, Icon2, BasicPlus2 WT, FHM-C1, RET, TP 5001 | Manifold systems, boiler-heated flats | Underfloor heating |
| Thermostatic radiator valves (~30) | RA-N, RA-FN, RA-DV, RAX, Tilde Regus, RLV, VHS | Radiator flow and return | Radiator valves |
| Control valves and controllers (~50) | VF, VRG, VZL, VFG, ECL Comfort, ESM sensors | Substations, plant rooms | Control valves |
Thermostatic radiator valves
The RA-N pre-setting body is designed for two-pipe systems; pre-setting runs from 1 to 7 plus the fully open N position. According to Danfoss data, maximum working pressure is 10 bar, maximum differential pressure 0.6 bar and maximum flow temperature 120 °C. RA-FN has no pre-setting and RA-DV is a pressure-independent body. Sensors include RAX (8–28 °C) and liquid-filled Tilde Regus heads.
Balancing valves
AB-QM is a pressure-independent balancing and control valve (PICV): it keeps the set flow even when differential pressure changes and works as a control valve with an actuator. ASV-PV is a differential pressure controller fitted in the return pipe; the DN15–DN50 version is adjustable from 20 to 60 kPa (factory setting 30 kPa). LENO MSV-BD and USV-I are static balancing valves for manual commissioning.
Actuators and motorised valves
This is the largest Danfoss group on our site. TWA-A thermal actuators fit RA-connection valves and underfloor manifolds, while TWA-K fits valves with an M30×1.5 connection. AME actuators accept 0–10 V modulating signals, AMV models use 3-point control. AMZ 112 (DN15–DN50) and AMZ 113 are 2-way and 3-way on/off motorised ball valves.
Danfoss heat meters
DN20 is the most common size for apartments. The SonoSafe 10 DN20 measures heating only: qn 2.5 m³/h, 130 mm length, 1″ thread, built-in M-Bus and optical interface, a free slot for a wM-Bus (OMS) or pulse module, MID class 2. SonoSelect is listed for heating and cooling. SonoMeter 40 (DN15–DN100) and Supercal 5 with Sono 3500CT flow sensors (DN125–DN600) cover larger pipes. See DN20 ultrasonic heat meters.
How to choose the right product
- Size and connection: confirm DN size and thread, flange, RA or M30×1.5 connection on site.
- Compatibility: the sensor or actuator must match the valve connection.
- Voltage and signal: 24 V or 230 V; on/off, 3-point or 0–10 V; normally open (NO) or normally closed (NC).
- Flow, pressure, temperature: compare design flow (l/h), differential pressure and PN rating with the order-code table.
- Metering: decide heating-only or heating/cooling and M-Bus or wireless M-Bus.
Frequently asked questions
Which sensors fit an RA-N valve body?
RA-N uses the Danfoss RA snap connection. According to the Danfoss data sheet it works with RA 2000, RAW and RAX sensors, and these combinations meet EN 215. The Tilde Regus heads on our site also have an RA connection. For actuator control, choose the RA-type TWA-A.
What is the difference between TWA-A and TWA-Q?
Both are 110 N thermal actuators for on/off or PWM control; the difference is the valve they fit. TWA-A fits Danfoss RA valves and manifolds (IP41). TWA-Q has an M30×1.5 connection and is made for AB-QM DN10–32 valves: 5 mm stroke, IP54, medium temperature up to 95 °C. Both come in 24 V and 230 V, NO and NC versions.
Which actuators can drive an AB-QM valve?
For AB-QM DN15–32, TWA-Q is used for on/off or PWM control and NovoCon S for modulating or networked control. NovoCon S runs on 24 V AC/DC and accepts analogue signals such as 0–10 V or 4–20 mA as well as BACnet MS/TP and Modbus RTU. NovoCon M, L and XL are listed for larger sizes.
How do SonoSafe 10 and SonoSelect differ?
SonoSafe 10 is a compact heating-only meter for apartments with built-in M-Bus and a free module slot. SonoSelect is listed for both heating and cooling metering. Both meet EN 1434 class 2; the DN20 versions share a 2.5 m³/h nominal flow and 130 mm length.
Prepared by the Novus Mühendislik ve Enerji Sistemleri technical team · Updated: November 2026