Calmet PM02-DN32 Ultrasonic Heat Meter
Calmet PM02-DN32 Ultrasonic Heat Meter
- Calmet PM02 ultrasonic heat meter
- Body size DN32 (1¼”), nominal flow rate Qn 6 m³/h
- Maximum flow rate qs 12 m³/h, minimum flow rate qi 60 l/h
- Body length (L) 180 mm, 1½” threaded connection (G1½B)
- Communication: Wired M-Bus (wM-Bus, LoRaWAN and pulse output versions available to order)
- Application: heating and cooling; installation point: supply or return line
- Temperature sensor: BOCON PT1000, with 1.5 m cable
- MID approval: Romania, accuracy class 2
- Pressure rating: PN16
Calmet PM02 Series
Calmet PM02 is an ultrasonic heat meter manufactured by FNF Teknoloji in Kayseri, Türkiye; it is used to measure heating and cooling energy in residential and commercial buildings.
The meter consists of a calculator unit, an ultrasonic flow sensor and a PT1000 temperature sensor pair with 1.5 m cables. It can be installed in the flow or return line, horizontally or vertically. The flow sensor has no moving parts.
Key Features (manufacturer data)
- MID approved (EU type-examination certificate RO-2275-23619), accuracy class 2 (EN 1434)
- Wired M-Bus (EN 13757-3) as standard; the manufacturer also offers wM-Bus, LoRaWAN and pulse output versions
- Medium temperature 5–90 °C, temperature difference 3–75 K; pressure rating PN16
- Protection class: calculator unit IP65, flow sensor and temperature sensors IP68
- 3.6 V lithium battery; 10 years according to the manufacturer
- Made in Türkiye: fast access to spare parts and service
Applications
- Large apartments, duplexes and office floors
- Commercial units and shops
- Sub-distribution lines within buildings
- Heat cost allocation and energy monitoring
Why Calmet PM02?
Calmet PM02 combines the fast supply and service of a meter made in Türkiye with MID-approved ultrasonic measurement. Using the same series from DN20 to DN100 makes it easier to manage all metering points of a residential complex with one reading infrastructure.
Installation, Reading and Re-verification
Install the meter in the position and at the mounting point specified in its manual; a strainer upstream of the meter and an isolating valve before and after it (for easy replacement) are recommended. In Türkiye, Novus Energy also provides remote meter reading and heat cost allocation services after installation. Periodic re-verification requirements for heat meters depend on local regulations; see our re-verification and calibration page for details.
Other models in the same size: DN32 heat meters · All products of the brand: Calmet · What is a heat meter and how do you choose one?
| Body Size (DN) | : | DN32 (1¼”) |
| Application | : | Heating, Cooling |
| Nominal Flow Rate (Qn) | : | 6.00 m³/h |
| Connection Size | : | 1½” Threaded |
| Communication | : | M-Bus (Wired) |
| Body Length (L) | : | 180 mm |
| MID Approval | : | Romania |
| Country of Origin | : | Türkiye |
| Temperature Sensor | : | BOCON PT1000 |